Low subcool high superheat

The outdoor temperature was 80°, and the liquid temperature was 82.4°, but the head pressure and subcooling were astronomically high due to a severe overcharge. The liquid line temperature was limited to just above the outdoor temperature. As more and more refrigerant was added to the system, the head pressure (and, therefore, the …

Low subcool high superheat. Superheat and Sub-Cooling. Whenever an HVAC technician needs to add refrigerant to a system or adjust the charge the tech needs to know what superheat and/or sub-cooling is to properly ensure the refrigerant charge is correct. It is also important to have a pressure-temperature or PT Chart to properly read the pressures and temperatures.

The saturation temperature on the low side was 28 degrees. I had a subcool of 20 and a superheat of 22. The delta T was 24F. The filter opening was 16X25 inches. The condenser coil look like it could use a cleaning. The fan amperage was 6.8.

Superheat and subcooling are the two fundamental concepts in any HVAC system. Basically, superheat is the temperature a refrigerant vapor needs to maintain its gaseous state as it passes through the evaporator coil. While subcooling is the additional cooling that takes place in a condenser after the refrigerant has already been condensed.Jan 23, 2018 ... Comments1 ; Low AC Refrigerant Charge - How to be SURE (Does it really need Freon?) HVAC School · 142K views ; Class - What Superheat Signifies.The increase in temperature above saturation is described as the refrigerant’s superheat value. For example, at 18.42 psig, R-134a has a saturation temperature of 20°F. If its measured temperature is 30°F, the refrigerant is said to be superheated by 10°F. One useful area to measure the refrigerant’s superheated value is at the exit of ...non combustables in system...had to reclaim entire charge ,and recharge to make it work rightThese are my readings 296psi high side, 95.8 lstat, 93.6 line temp, 2.3 subcool. 140.6psi low side, 50.1 vstat, 51.3 line temp, 1.2 superheat. 20degree delta tee across the return and supply. I may have missed something somewhere, but all that looks like an overfeeding TXV. 50˚ saturated suction pretty much eliminates low airflow, particularly ...Jan 13, 2023 · In many cases, a low superheat and high subcool is caused by excessive refrigerant charge in air conditioning systems. The problem can be fixed by discharging excess refrigerant from an air conditioning system. AC refrigerant lines. In this guide, we are going to look at what low superheat is and what causes it. Post Likes. Low subcooling results when there is insufficient refrigerant to fill the lower part of the condenser coil. High suction superheat results when there is insufficient refrigerant to fill the evaporator properly. If you have insufficient refrigerant in both places - it is likely that the system is undercharged.System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.

A system with low superheat and high subcooling has too much refrigerant. The two previous conditions we looked at had high superheat. Low superheat shows too much refrigerant in the evaporator, and it cannot boil it off fast enough. The excess refrigerant could easily make it back to the compressor and cause permanent damage from flood back ...on target subcool with high superheat could mean a few things. 1. charge is low and condenser is underperforming 2. evap/condenser performing normally, but low charge takes txv out of range 3. low charge with restricted metering device. Reply . 06-07-2020, 11:28 PM #18. Adlerberts-Protege.While you may have heard the income gaps in the United States are getting larger, you might not know what earning level is considered low income. No matter where you live and how m...Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in Birmingham, AL. Bryan also talks a bit about his educational photo-sharing app, MechPic. The suction pressure and suction saturation give us an idea of the refrigerant's boiling temperature. If I have my theroy right I have a low superheat of 10 and a high subcooling of 21. Ambiant temp outside is 81 and all temps are in F. 19-07-2011, 03:16 AM #40. Subcooling. The term subcooling (also called undercooling) refers to a liquid existing at a temperature below its normal boiling point. For example, water boils at 373 K; at room temperature (293 K) liquid water is termed "subcooled". A subcooled liquid is the convenient state in which, say, refrigerants may undergo the remaining stages of a ...September 14, 2001. The dire ramifications of under- and overcharging an air conditioner or heat pump were covered last month ("Using the Superheat Method to Charge A/C Systems,"The News, Aug. 13, page 1). The first installment also contained a basic explanation of what superheat is and what it tells you about the condition of the evaporator coil.

Match high side manifold gauge reading (discharge pressure) For SuperHeat or Low Side PT Data For SubCool or High Side PT Data. Replacement parts/accessories 69214 - 3' clamp thermocouple probe 69217 - 10' clamp thermocouple probe Covered by a one year warranty from the date of sale.Aug. 24, 2016. Don't always assume you have to "add refrigerant." Consider the three main causes of low suction pressure, and check superheat and subcooling to make the correct diagnosis. Skip …New Guest. Join Date. Sep 2012. Posts. 2. Post Likes. How to interpret high Superheat + low subcooling? Hi, every one, I'm new in HVAC, please help me to diagnose my home …1. Low Refrigerant Charge (Most Common Cause) The most common cause for high superheat is low refrigerant charge. Namely, if our AC unit doesn’t have enough freon, you will see that the metering device will underfeed the evaporator coil. Now, there is not enough refrigerant in the evaporator coil.Subcooling is when the liquid refrigerant in your is colder than the minimum temperature required to keep it from boiling. This can happen when the system is first turned on, or if there's a problem with the system. When this happens, the liquid refrigerant can change from a liquid to a gas phase, which can cause problems with the HVAC system.

Flirty meme for her.

No subcooling and no superheat usually means it's flooding, which does point to the evap side of the system. Orfice/txv , airflow most obvious to check first. Reply. 08-14-2016, 04:53 PM #15. smee123. Regular Guest. Join Date.Evaporator Superheat Method: 1. Take the suction line pressure and temperature at the condenser's suction service valve (air conditioning) or service port at the compressor (heat pump). If you use a probe-type thermometer, put a …With the Superheat/Subcool Calculator off, press the POWER button. 2. Press and hold the UNITS button for two to three seconds until the current temperature unit is displayed. 3. Use or to select the desired temperature unit. ... For SuperHeat or Low Side PT Data For SubCool or High Side PT Data. Title: 405199_Rev.D Created Date:Troubleshooting, Heat Pump, AC. In this video, I use a job check out sheet of complete system run data to determine what is wrong with the system using subcooling and superheat. Metering device is a Piston.The fix. How to Check For Superheat. What is subcooling and what does low subcooling mean? Chart for low subcooling causes and possible fixes. 1) Defective metering device. The fix. 2) Poor compression. The fix. 3) Refrigerant Undercharge. 4) Restricted airflow to the condenser. The fix. How to Check Subcooling.

Aug. 24, 2016. Don't always assume you have to "add refrigerant." Consider the three main causes of low suction pressure, and check superheat and subcooling to make the correct diagnosis. Skip …23. Post Likes. In low ambient conditions the reason the subcooling rises so much is because it starts to stack in the condenser. The reason for this is refrigerant is attracted to the coldest place in the system. During the winter the ambient conditions get below the temperature at the evaporator causing the refrigerant to naturally want to ...Superheat and subcooling are the two fundamental concepts in any HVAC system. Basically, superheat is the temperature a refrigerant vapor needs to maintain its gaseous state as it passes through the evaporator coil. While subcooling is the additional cooling that takes place in a condenser after the refrigerant has already been condensed.Subcooling is when the liquid refrigerant in your is colder than the minimum temperature required to keep it from boiling. This can happen when the system is first turned on, or if there's a problem with the system. When this happens, the liquid refrigerant can change from a liquid to a gas phase, which can cause problems with the HVAC system.System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.That's because low charge results in high superheat AND low subcooling (we have covered this in high superheat low subcooling issues here). We are left with only 2-3 culprits that can actually cause both high superheat and normal subcooling. These are: Too high indoor CFMs. Too high indoor load. Faulty measurement. Let's look at all these 3 ...So low airflow (dirty coil, filter, high static pressure etc) means you don't get the same volume of air, which naturally results in low heat gain low superheat. High superheat, e.g. low charge, you don't have enough refrigerant to pick up the heat efficiently, resulting in longer runtimes (higher power bill) and an exponentially less ...Saying you've never had a problem setting charge when if you don't charge by subcool on a txv then you literally didn't properly charge the system. Oh and there is no reason to believe that superheat is low. Even if it was a piston system depending on load conditions 8 superheat is not only perfectly acceptable… it can be required.Here is a table with these causes that will help us understand why we get low superheat normal subcooling: Low Superheat Causes: Non-Normal Subcooling Causes (High Or Low): Indoor airflow (CFMs) is too low. Oversized AC unit. Outdoor airflow is too low (or condenser coils heat exchange is impeded). High refrigerant charge (overcharged AC unit).In this clip I discuss my measurements while testing a 13 SEER American Standard in heat mode.

28. Post Likes. high super heat low suction. any ideas. I am working on a ruud heat pump. Freeze up problems. Low suction pressure, 24 superheat, 8 subcooling. 14 degree air drop across my coil. I have evacuated and wieghed in a charge r-22 and replaced txv. No kinks in line set and not a plugged filter dryer. .5 static pressure across my coil.

A solid understanding of superheat and subcooling is essential. Troubleshooting often requires simultaneous knowledge of temperature, pressure, voltage, and current values in a system. A single-function meter won't permit a complete analysis of the system. Frequently, multiple tools are required. This article provides information on ...The increase in temperature above saturation is described as the refrigerant’s superheat value. For example, at 18.42 psig, R-134a has a saturation temperature of 20°F. If its measured temperature is 30°F, the refrigerant is said to be superheated by 10°F. One useful area to measure the refrigerant’s superheated value is at the exit of ...Bryan teaches a class about what superheat signifies. Superheat is the difference between a vapor's actual temperature and its suction saturation temperature; it lets us know how much an HVAC system feeds its evaporator coil with boiling refrigerant. Liquid refrigerant goes into the metering device, and there needs to be enough liquid going ...Superheat determines by how many degrees of temperature refrigerant vapor increases in the system. We are usually looking for 7°F to 15°F superheat.Too low superheat (below 2°F) = Risk of flooding the compressor, too high superheat (above 15°F) = Risk of overheating the compressor.More about that in our general superheat and subcooling article here.It's simply shedding heat energy, moving left all the way through the saturation dome, and even subcooling the refrigerant slightly at the end. Point 3: The "throttle" is the metering device that separates the high-pressure condenser from the low-pressure evaporator -- usually a thin capillary tube in household refrigerators. As the refrigerant ...The nucleate boiling suppression factor, S, is the ratio of the effective superheat to wall superheat. It accounts for decreased boiling heat transfer because the effective superheat across the boundary layer is less than the superheat based on wall temperature. The two-phase multiplier, F, is a function of the Martinelli parameter χ tt.Superheat is then any temperature of a gas above the boiling point for that liquid. When a refrigerant liquid boils at a low temperature of 40 degrees in a cooling coil and then the refrigerant gas increases in temperature superheat has been added. If this refrigerant changed from a liquid to a gas or vapor at 40 degrees and then the refrigerant

When does spm get out.

Jane treacy reviews.

Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.The nucleate boiling suppression factor, S, is the ratio of the effective superheat to wall superheat. It accounts for decreased boiling heat transfer because the effective superheat across the boundary layer is less than the superheat based on wall temperature. The two-phase multiplier, F, is a function of the Martinelli parameter χ tt.Share this Tech Tip: Suction pressure, head pressure, subcooling, superheat, delta T. Taking all five of these calculations into account on every service call is critical. Even if you must do further diagnostic tests to pinpoint the problem, these five factors are the groundwork before more effective diagnostics can be done.Hey my fellow tech. I recieved a call today that the unit was freezing over on a old carrier unit. So i went through the protocol, IDM, Filter, Evap coil, ductwork, all checked out good. Before i continue recommend every tech to go get the testo 550 they're so nice. Anyhow hooked up my testo to the unit the unit and checked my superheat sence it had cap tubes.What causes Low superheat with high subcool. When both low superheat and high subcooling occur simultaneously, it signals a unique condition that can only be attributed to an overall excess of refrigerant in the system. Overcharging the air conditioning system with refrigerant is the primary cause of experiencing both low superheat and high ...I'm a new tech and I am confused about subcool and liquid line restrictions. I've read that a unit that is low on charge will have low subcool and high superheat. Units that have LL restrictions but a good charge will have good subcool, around 10 degrees, and high superheat.If the metering device is a fixed orifice such as a piston or capillary tube, the refrigerant charge of the system can be checked with Total Superheat. If the metering device is a TXV then the refrigerant charge can be checked with Subcooling. See the Picture below. If the unit has a TXV, check for the Target Subcooling posted at the outdoor unit.How to Calculate Superheat. 1. Obtain suction line temperature: First, measure the temperature of the suction line near the evaporator outlet using a digital thermometer or a clamp-on thermocouple. 2. Determine saturation temperature: Next, read the low side pressure gauge on your HVAC gauges while equipped with corresponding refrigerant scale ...Buy HIATSU Digital Manifold Gauge HVAC Refrigeration Heavy Duty with 2 Wired Temperature High Low Side Pressure Measurement Superheat Subcooling 3 Hose Refrigeration Support 88 Types of Refrigerants: Air Conditioning Line Repair Tools - Amazon.com FREE DELIVERY possible on eligible purchasesFreezer superheat and subcooling. Hello HVAC tech I am working on a walk in freezer box temp is -10 degrees. this is a R402A refrigerant unit by Larkin it is a Copeland compressor. My suction temp. at the compressor is 33.7 the saturated temp is -32 at 10 psi. the High side is 215 psi saturated temp 89 degrees and the pipe temp is 91 …This is important because, in cool mode, a dirty air filter caused low airflow on the evaporator. In those cases, you would typically notice a low suction pressure and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. That can cause extremely high head pressure. In heat mode, a dirty outdoor coil can ... ….

Superheat Good Subcool Good High SH Low SC ... High Low Low Low High Over-Charge High High Restricted Low Low Over-feeding Only evaluate charge after the airflow has been confirmed to be accurate and coils are confirmed to be clean. College of HVAC Education . Title: Microsoft Word - Thumb Chart complete.doc ...A high superheat, a warm suction line, and 0 degrees subcooling in an A/C system likely indicate a low refrigerant charge. These symptoms show inefficient heat absorption in the evaporator and inadequate refrigerant to condense in the condenser. Therefore the correct answer is: A) Explanation:Calculating superheat can tell us how far liquid Freon is traveling through an evaporator coil. If superheat is too high, there's less liquid and more gas in the coil. This can cause overheating. If superheat is too low, more liquid and less gas are in the coil. This can cause flooding and damage in the compressor.A high superheat is an indication of either a low refrigerant charge or a liquid line restriction problem. To tell the difference between the two problems, we look at subcooling. A system with a low refrigerant charge will have a low subcooling. A system with a liquid line restriction will have a normal to high subcooling.In this HVAC Training Video, I show how to Measure Both Superheat and Subcooling Without Measuring Pressure. I Compare Measuring Pressure with Temperature On...Your suction gauge is reading too high. Your line clamp thermometer is reading too low. You do not have a good connection on the line, the Schrader core isn't depressing, or the King valve isn't open. A combination of the items listed above. Negative Subcooling . Just as we mentioned above, negative subcooling is actually a superheat condition ...162. 25. I know that having both high superheat and low subcooling on an Air-Conditioner (A/C) is a strong indication that an air-conditioner does not have enough refrigerant. When the charge on an A/C is low, there is less refrigerant that enters the evaporator. When there is a lower amount of refrigerant entering the evaporator, it takes …When it comes to purchasing a vehicle, finding an affordable option is often at the top of many buyers’ lists. Two popular choices for budget-conscious individuals are low-cost car...High side pressure and subcool become the determining factor in charging because of the TXVs ability to change flow rate. Superheat still can be measured though to determine if a TXV is operating properly. Some TXVs can be manually adjusted to change spring pressure and flow rate. ... Low Charge- If refrigerant charge is low, the … Low subcool high superheat, 28. Post Likes. high super heat low suction. any ideas. I am working on a ruud heat pump. Freeze up problems. Low suction pressure, 24 superheat, 8 subcooling. 14 degree air drop across my coil. I have evacuated and wieghed in a charge r-22 and replaced txv. No kinks in line set and not a plugged filter dryer. .5 static pressure across …, That’s because low charge results in high superheat AND low subcooling (we have covered this in high superheat low subcooling issues here). We are left with only 2-3 culprits that can actually cause both high superheat and normal subcooling. These are: Too high indoor CFMs. Too high indoor load. Faulty measurement. Let’s look at all these 3 ..., Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level (atmospheric pressure of 14.7 PSIA). If water is 212°F and at atmospheric pressure at sea level, you can be sure it is at saturation, which means it ..., The following can, in theory, cause high subcooling, but effects are minimal: Low condenser air flow on TXV metering; High ambient on TXV metering; Low subcooling (aka a "starved condenser") can be caused by many things, but some culprits to check are: Low charge; Long liquid lines; High vertical separation; Liquid lines exposed to high ..., Lots of people saying check airflow, but low airflow cannot lead to high superheat. The refrigerant is entering the evaporator at 23°, but it's 70° by the time it leaves. What is warming it up, if not airflow? The only realistic way to have both high superheat and low subcool is low charge., The result is low superheat. Here is how we fix low superheat due to overcharged AC unit: We have to remove the refrigerant (R-22, R-410A, R-134A, etc.). This is simple to say but hard to do. We have to leak the AC unit, and that job is best left to licensed HVAC technicians (with a license to drain freon). This is not a DIY low superheat fix., Signs of Low Subcooling High suction pressure. One sign of low subcooling is high suction pressure in your HVAC system. When there’s not enough subcooling, the refrigerant pressure in the system can become elevated, which can lead to poor cooling performance and potential damage to your system. Low discharge pressure, The best answer is—as usual—whatever the manufacturer says it should be. If you really NEED a general answer, you can generally expect: High Temp or A/C systems to run 6-14°F of superheat. Medium Temp – 5-10°F. Low Temp – 4-10°F. Some ice machines and other specialty refrigeration may be as low as 3°F of superheat., Adjusting Superheat and Subcooling Values Troubleshooting high superheat. If your superheat value is too high, it might be due to issues like low refrigerant charge, dirty evaporator coils, or an incorrect metering device. It’s like trying to find the cause of a flat tire – you need to inspect and fix the problem! Troubleshooting low superheat, Freezer superheat and subcooling. Hello HVAC tech I am working on a walk in freezer box temp is -10 degrees. this is a R402A refrigerant unit by Larkin it is a Copeland compressor. My suction temp. at the compressor is 33.7 the saturated temp is -32 at 10 psi. the High side is 215 psi saturated temp 89 degrees and the pipe temp is 91 …, Suction pressure, head pressure, subcooling, superheat, delta T. ... If the leaving temperature/delta T split is high, it is an indication of low airflow. If it is low, it is an indication of poor system performance/capacity. Again, this only applies to 400 CFM per ton. Systems set at 350 CFM per ton or less are more common today than ever ..., Subcooling: It's the process of cooling refrigerant below its saturation temperature. Subcooling increases the efficiency of your HVAC system by making sure the refrigerant is fully condensed before it enters the evaporator. Superheat: This is when the refrigerant gets heated above its boiling point. Superheat prevents liquid refrigerant from ..., 8-12* superheat would be what you want to shoot for. higher the superheat, the more starved the evaporator is. you definitely have to factor in them long linesets. if you can get the superheat down to the margin, roll with it. you will know your overcharged if your superheat falls below the margin., Superheat is then any temperature of a gas above the boiling point for that liquid. When a refrigerant liquid boils at a low temperature of 40 degrees in a cooling coil and then the refrigerant gas increases in temperature superheat has been added. If this refrigerant changed from a liquid to a gas or vapor at 40 degrees and then the refrigerant, New Guest. Join Date. Sep 2012. Posts. 2. Post Likes. How to interpret high Superheat + low subcooling? Hi, every one, I'm new in HVAC, please help me to diagnose my home …, Had a superheat of 2 degrees which seemed very low. Unit upon arrival seemed undercharged as stated. Began doing this when refrigerant was added. Prior to adding refrigerant only had subcooling of 1-2 degrees. Achieved 10 degrees subcooling and began doing this and made the odd noise everytime it reached over 100 degrees saturation on high side., If superheat is high and sub-cooling is low: Charge must be adjusted. System undercharged. If superheat is low and sub-cooling is high: Charge must be adjusted. System overcharged If superheat is high and sub-cooling is high: Could have blockage in coil, orifice or line set., Attach the Manifold Gauges. Connect the manifold gauges to the low-pressure port. Ensure it is attached securely to prevent any leakages and to get accurate readings. Take Temperature and Pressure Readings. Using a thermometer, take the temperature reading of the suction line — this is the line that carries the refrigerant back to the unit., Superheat and subcooling are complementary processes in refrigeration systems, where superheat ensures the refrigerant vapor is heated beyond its boiling point for efficient compression while subcooling cools the refrigerant liquid below its condensation point to enhance heat exchange efficiency. ... However, when the reading is too high, there ..., Step 4: Measure Initial Superheat. Before making any adjustments to the TXV, you'll need to establish a baseline by measuring the existing superheat. Attach a temperature probe to the suction line near the evaporator coil. Note down the temperature reading. See also Compressor Short Cycling: 6 Proven Solutions., Starving the evaporator Increasing the system superheat Decreasing the system subcooling Increasing the operating head pressure and compression ratio Question 26 1. In general, air source heat pumps are sized to meet The building cooling capacity The sum of the building heating and cooling capacity Whichever is largest, the cooling capacity or ..., Low heat loads on the condenser mean low condenser splits. Normal to a Bit High Condenser Subcooling — Most of the refrigerant will be in the receiver, with some in the condenser. The condenser subcooling will be normal to a bit high because of this. The refrigerant flow rate will be low through the system from the restriction., To make the adoption of low-code technology hassle-free, this platform comparison guide covers a lot of basic as well as more advanced information to evaluate the top low-code plat..., For superheat measurement, we use the blue low side gauge. The red one (high side) is for measuring subcooling on the liquid line. Needless to say, we: Don’t want a very low superheat (0°F, 1°, or 2°F) since this indicates liquid refrigerant might be entering the compressor. The compressor can only handle vapor, not liquid., Low Superheat Low Subcooling: Learn To Fix It. Low superheat and low subcooling are the indicators for your evaporator to be low on heat and have a limited refrigerator in its condenser. We will recommend you maintain a suitable climate around your Living area in order to feel comfortable. Tom Moore May 19, 2023 — 5 minutes read., Normal indoor TD. High suction pressure, subcooling, head pressure & compressor current draw. LOW INDOOR AIR FLOW = Low superheat & suction pressure. Low to normalhead pressure. Highindoor TD. High to normalsubcooling. Not much effect on current draw. MILD LOW OUTDOOR AIR FLOW = Low superheat & subcooling. High suction & head pressure., A suction pressure temperature reading of 45ºF and a suction line temperature of 56ºF tell you that there is 11ºF of superheat. This reading, in particular, can also demonstrate that …, Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in..., non combustables in system...had to reclaim entire charge ,and recharge to make it work right, Hello I have a 20 TON AAON Split coil condenser, each compressor is 10 tons. Unit is R410A. Semi annuals have just been done on the unit so all coils and filters are clean. Outdoor air was 93, indoor was 67. Condenser has 2 fans and both are running at proper speed. The high superheat and low subcooling would normally suggest to me that the unit is low on Freon and needs to be charged, but my ..., 4 Using Table 2, select the column which is closest to the measured vapor pressure. 5 Scroll down the column to find your calculated superheat. 6 Read the required vapor line temperature at the intersection. (°F) If the measured vapor line temperature does not agree with the required vapor line. 7 temperature, add refrigerant to lower ..., Starving the evaporator Increasing the system superheat Decreasing the system subcooling Increasing the operating head pressure and compression ratio Question 26 1. In general, air source heat pumps are sized to meet The building cooling capacity The sum of the building heating and cooling capacity Whichever is largest, the cooling capacity or ..., A unit that is overcharged will have a low superheat temperature and a high subcooling temperature. With low superheat, there is a risk of the refrigerant passing through the evaporator too quickly with liquid refrigerant finding its way back to the compressor. This can cause the compressor to fail. High subcooling will also damage the compressor.