Trane chiller tonnage by model number

Parts & Supplies. At Trane Supply, we have the parts and the knowledge to support all of your HVAC needs, no matter what system you are working on. You can rely on us to deliver a solution to meet your customers’ needs, and to help you be more productive, profitable, and knowledgeable. Along with our technical expertise, we focus on providing ...

Trane chiller tonnage by model number. to recommend the model RTHD helical-rotary liquid chiller.This chiller provides application versatility,easeofinstallation,controlprecision,reliability,energyefficiency,andoperationalcost-effectiveness.The RTHD chiller is designed to deliver proven performance, plus all the benefits of

To meet a wide range of applications in the 65–125 ton water-cooled market, Trane is proud to introduce the model RTWS helical-rotary liquid chiller. The introduction of this next-generation ... Model Number Descriptions 10 General Data 12 Performance Data 13 Controls 16 Electrical Data 19 ... With the model RTWS chiller, condenser head …

By dividing the seventh and eighth digits of the model number by 12, you may determine the outdoor unit’s capacity in tonnes for a certain Trane model. If the model …To meet a wide range of applications in the me dium-tonnage, water-cooled market, Trane is proud to recommend the model RTHD helical-rotary liquid chiller.This chiller provides application versatility, ease of installation, control precision, reliability, energy efficiency, and operational costeffectiveness.The RTHD chiller is designed to delive... Trane’s air-to-water heat-pump chiller provides cooling or heating from one all-electric source, making it an effective—and more affordable—way to decarbonize. 3X more efficient. Ascend model ACX brings Trane’s proven, economical heat pump technology platform up to scale to provide heating or cooling for larger commercialThese CenTraVac chillers are among the Trane products within the EcoWise™ product portfolio and can operate with either R123 or next-generation refrigerants R514A or R1233zd, both featuring ultra-low global warming potential (GWP) of less than 2. Most Efficient - Selectable commercial chiller with full load efficiencies down to 0.45 kW/ton at …Hi, Does anyone have access to a Trane service manual ? Twin Helirotor compressors. Lead compressor tripping (every few days) on high oil ...Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient temperatures of 25 to 115°F (-4 to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If an©2021 Trane RLC-PRC029K-EN Introduction To meet a wide range of applications in the 75-240 ton water-cooled market, Trane is proud to offer the model RTWD helical-rotary liquid chiller. To me et a wide range of applic ations in the 70-200 ton condenserless market, Trane is offering the RTUD condenserless chiller. This next-generationAug 1, 2023 · Every model in the M Series has a corrosion-resistant finish. This sleek finish will keep your air handler looking new, even after 10 or more years of use. Plus, this model comes with an efficient, three-speed motor and a no-rust polymer drain pan. The model is available in 1.5 to 5-ton sizes.

Earthwise™ Ice-enhanced, Air-cooled Chiller Plant; Intelligent Variable Air System for Packaged DX Applications; Intelligent Variable Air System for Chilled-Water Applications; Low Flow, Low Temperature CenTraVac™ Chilled-Water System ; Product Literature. Product Literature (EN) User ManualsParts & Supplies. At Trane Supply, we have the parts and the knowledge to support all of your HVAC needs, no matter what system you are working on. You can rely on us to deliver a solution to meet your customers’ needs, and to help you be more productive, profitable, and knowledgeable. Along with our technical expertise, we focus on providing ...Re: Trane Water chiller model number. check your model in cats and there are models that model CGAFC, CGAFW, CGAFD WHAT IF YOU CAN SAY THAT FOR DIGIT IS THE NUMBER OF 40TR. 23-06-2010, 11:32 AM #9. Hoaster Guest. A chilled-water applied system uses chilled water to transport heat energy between the airside, chillers and the outdoors.of Model CVGF, 50 Hz and 60 Hz chillers with the AdaptiView Controls platform. See Figures 2 and 3 for an illustration of a CVGF Centrifugal Chiller with the Adap-tiView Unit Control Panel. These chillers are equipped with microcomputer-based control systems. A careful review of this information along with the submittaltrane chiller model & serial number assistance - hvac-talk Web Mar 14, 2018 Model - CVHE-028F-AG-2KB2533CE1C13CEZ00000000061C00 Serial # L85E28540 Chiller Two: Model - CVHE-028F-AG … From hvac-talk.comCode HPhaseolts P 1223 P 125 T5 3223 TD 34 TE 355 Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1.5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5

Jun 21, 2016 ... ... models operating with low Global Warming Potential (GWP) refrigerants ... Trane now offers CenTraVac heavy-tonnage chillers for applications ...MODEL. 4TTZ0024A1 4TTZ0036A1 4TTZ0048A1 4TTZ0060A1. TONS. ... Trane 2/4TEE Air Handler: ... 4 Ton 5 Ton. Cooling Capacity (BTHU) 18,000 BTHUView AC unit costs and the cost for a new furnace and find out the price of a new unit before you contact a Trane technician. ... More energy-efficient models save you energy and monthly costs. 45%. 39%. 36%. 45%. 39%. 36%. ... Phone Number. Next.Carrier’s comprehensive line of water-cooled equipment are designed to enable chiller plants to achieve superior efficiency at true operating conditions without compromising the environment. These units boast integrated part-load values (IPLV) to 0.288 and full load kW/Tons to 0.505 while utilizing either HFC-134a, HFC Puron® or HFO-1233zd (E).The Trane model number is #TWE030C140B0, let’s try to decode this model number: TW = split component heat pump compatable. E = Electric furnace (like they said, heat strips are added in the field, could be anything from 10kw to 25 kw) 0 = Brazed refrigeration connection. 30 = 2.5 ton like you mentioned.

Ubg365 github io unblocked.

Chiller Trane RTHC Installation Operation & Maintenance. 175-450 ton units (60 hz); 125-450 ton units (50 hz) (168 pages) Chiller Trane RTHA Installation, Operation And Maintenance Manual. Solid state starter conversion (48 pages) Chiller Trane RTCA 108-216 Installation And Operation Manual.Decoding Trane model number has never been this easy, thanks to the creation of the HVAC Decoder App. The HVAC Decoder App does all this for you; just enter the model number and get the results. Example Trane Model Number: TUD2B060A9V3VB. The results from the HVAC Decoder App are shown below.Trane expands chiller portfolio for European markets · Trane RTHDevo - Water cooled liquid chillers with helical-rotary compressors · Trane Sintesis - air-cooled ...Our chillers serve HVAC systems that deliver the right temperature, humidity and ventilation for the space, but they also help minimize operating costs with superior energy efficiency levels, low sound levels and with minimal environmental impact. water-cooled-rthd-chiller.jpg.We have 1 Trane YCH600 manual available for free PDF download: ... Model Number Description. 14. General Data. 15. Performance Adjustment Factors. 18. Performance Data. 19. ... Air Conditioner Heat Pump Chiller Air Handlers Thermostat. More Trane Manuals . manualslib. Our app is now ...Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient …

AC Tonnage = 2.5 Tons. You can get AC tonnage by the general estimation that the digits “30” indicate 30,000 BTU of cooling capacity in your air conditioner. As 12,000 BTU is the cooling capacity of a one-ton unit, dividing 30,000 by 12,000 will directly give you 2.5 as result.Điều hòa chiller trane. Helical Rotary Liquid Chiller 125-450 Ton 423.000.000 đ Tiết kiệm điện: Chiller Trane. Model: RTUD 80 to 250 Tons. 289.000.000 đ Tiết kiệm điện: Chiller trục vít Trane. Model: CGAM 20 to 130 tons (50 and 60 Hz) 98.000.000 đ Tiết kiệm điện: Điều hòa Chiller Trane giải nhiệt nước.Chiller Trane R Series Installation Operation & Maintenance. Helical rotary liquid chillers. 175-450 ton units (60 hz) 125-450 ton units (50 hz) (184 pages) Chiller Trane RTHD Troubleshooting Manual. Air and water cooled chillers (74 pages) Chiller Trane RTHA Installation, Operation And Maintenance Manual. Solid state starter conversion (48 pages)WarrantycoversCenTraVac™chillers(modelsCDHF,CDHH,CVHE,CVHF,CVHH,CVHL,CVHM, andCVHS)installedintheUnitedStatesandCanadathatshipfromthefactoryinLaCrosse, Wisconsin,September1,2004orlater.TThheeCCoommppaannyy''ssoobblliiggaattiioonnssaannddlliiaabbiilliittiieessuunnddeerrtthhiissAug 10, 2016 · Trane Tonnage from Model Number. TTP018 = 1-1/2ton; TTP024 = 2 ton; TTP030 = 2 1/2 ton; TTP036 = 3 ton; TTP042 = 3 1/2 ton; TTP048 = 4 ton; Example of Trane Model Identification. The Trane model number is #TWE030C140B0, let’s try to decode this model number: TW = split component heat pump compatable IntelliPak rooftop units set the bar for durability and value. With a portfolio of three distinct products and industry leading efficiencies, the Intellipak product is designed to serve a range of application and regulatory needs. IntelliPak 1 - 20-130 Tons. IntelliPak 2 - 90-150 Tons. IntelliPak 3 - 20-75 Tons.Let Cold Shot Chillers® help you properly estimate and then manufacturer the perfect chiller for your specific ... Properly sizing a chiller for your application can depend on a large number of variables. ... Ton Capacity = 239,904 BTU/hr. ÷ 12,000 = 19.992 Tons; Oversize the chiller = 19.992 x 1.2 = 23.9904; A 23.9904 or 25-Ton chiller is ...The Series L™ CenTraVac™ chiller (model CVHL) is a direct result of the Trane commitment to provide the right technology for the right application at the right time. Because industrial processes and data center applications have unique cooling requirements, the Our chillers serve HVAC systems that deliver the right temperature, humidity and ventilation for the space, but they also help minimize operating costs with superior energy efficiency levels, low sound levels and with minimal environmental impact. water-cooled-rthd-chiller.jpg.The chiller is designed to deliver proven Trane performa nce based on the redesign of a European model that has been a market leader, plus all the benefits of new heat transfer and fan desi gns, as well as, low-speed, direct-drive scroll compressors. Important Design Features and New FeaturesWe create comfortable, energy efficient indoor environments for commercial and residential applications.

Water-Cooled Helical Rotary Chiller. At a glance. Capacity Range: 80 to 450 tons, 60 Hz; 60 to 450 tons, 50 Hz. Refrigerant: R-134a or R-513A. Best Full-load Efficiency: 0.6200 kW/ton (at AHRI conditions) Best Part-load Efficiency: 0.4800 kW/ton. Compressor Type: Helical Rotary. Medium Pressure. Agility_ISO Right_ Front_V02_F 2.jpg.png.

The Series L™ CenTraVac™ chiller (model CVHL) is a direct result of the Trane commitment to provide the right technology for the right application at the right time. Because industrial processes and data center applications have unique cooling requirements, theconcept minimizes the chance of failure by reducing the number of critical parts—no gear boxes, couplings, extra ... † Updated minimum and maximum evaporator flow rates for all models. Capacity (Tons): 500 1000 1500 2000 2500 3000 3500 4000 ... Trane chillers are frequently used in conjunction with combustion turbines to incr ease ...©2022 Trane RLC-PRC049K-EN Introduction The new Trane® Sintesis™ model RTAF chiller is the result of a search for higher reliability, higher energy efficiency, and lower sound levels for today’s environment. Sintesis™ is the newest member of Ingersoll Rand’s EcoWise™ portfolio of Find the model number. Within this string of letters and numerals, you should find an even, two-digit number. The capacity in tons of a Trane outdoor unit can be determined by dividing the 7th and 8th digit of the model number by 12. So if the model number is #4TTX4036A1000AA, take 36 and divide by 12, equaling 3 tons. Lets decode the trane ...Jun 7, 2023 · First letter. The model number starts with 4. This number represents the type of refrigerant the unit uses. 2 stands for R-22 and 4 stands for R410A. Second letter. T stands for Trane. The third letter represents the product type. T stands for split cooling. The fourth letter equals the product family. Web 15-80 tons (800 ton bank) Model MWC standard efficiency 20-40 tons (400 ton bank) Model MWT high efficiency Provides cooling Heat recovery option available Available … From trane.com See detailsTrane YSC120 Pdf User Manuals. View online or download Trane YSC120 Installation Operation & Maintenance. Sign In Upload. Manuals; Brands; Trane Manuals; ... Model Number Description. 2. Table of Contents. 3. Unit Nomenclature. 4. Model Number Description. 4. General Information. 5. Unit Nameplate. 5. Compressor Nameplate. 5. ...©2022 Trane RLC-PRC020K-EN Introduction To meet a wide range of applications in the me dium-tonnage, water-cooled market, Trane is proud to recommend the model RTHD helical-rotary liquid chiller.This chiller provides application versatility, ease of installation, control precision, reliability, energy efficiency, and operationalACX. Enabled by Symbio® 800 wireless connectivity. Capacity Range: 140 to 230 tons cooling; 1500 to 2500 MBh heating. Refrigerant: R-454B. Heating fluid temperatures up to 140F. Heating operation down to 0F ambient. ASHRAE 90.1-2019 compliant.

Time now in texas usa.

V bucks gift card code.

Chiller Trane R Series Installation Operation & Maintenance. Helical rotary liquid chillers. 175-450 ton units (60 hz) 125-450 ton units (50 hz) (184 pages) Chiller Trane RTHD Troubleshooting Manual. Air and water cooled chillers (74 pages) Chiller Trane RTHA Installation, Operation And Maintenance Manual. Solid state starter conversion (48 pages)Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient temperatures of 25 to 115°F (-4 to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If an IntelliPak rooftop units set the bar for durability and value. With a portfolio of three distinct products and industry leading efficiencies, the Intellipak product is designed to serve a range of application and regulatory needs. IntelliPak 1 - 20-130 Tons. IntelliPak 2 - 90-150 Tons. IntelliPak 3 - 20-75 Tons.Packaged systems. Simplify your comfort with all-in-one HVAC systems that bundle heating and cooling components in a single box. Unlike split systems, these systems only use one outdoor unit and work best in mobile and modular homes or homes without basements or attics. Gas & electric packaged. Create optimal comfort with an air conditioner and ...Carrier’s comprehensive line of water-cooled equipment are designed to enable chiller plants to achieve superior efficiency at true operating conditions without compromising the environment. These units boast integrated part-load values (IPLV) to 0.288 and full load kW/Tons to 0.505 while utilizing either HFC-134a, HFC Puron® or HFO-1233zd (E).Jul 22, 2022 · Trane age of unit – here is how to read a Trane serial number: For units made from 2002 to 2009 , the first number represents the year: 2 is 2002, 3 is 2003, etc. The next two numbers are the week of the year, so 01 would be the first week in January, and 52 would be the last week in December. Packaged systems. Simplify your comfort with all-in-one HVAC systems that bundle heating and cooling components in a single box. Unlike split systems, these systems only use one outdoor unit and work best in mobile and modular homes or homes without basements or attics. Gas & electric packaged. Create optimal comfort with an air conditioner and ... Trane air-cooled Series R® chillers are designed for year round operation over a range of ambient temperatures. The Model RTAC chiller will operate as standard in ambient temperatures of 25 to 115°F (-4 to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If anoperation and reduced chiller installation and maintenance time. † Trane CH530™ with Adaptive Controls™ have improved fan algorithms for more reliable operation at extreme conditions. † Single chiller time of day scheduling communication for easier control of small jobs. ….

The chiller is designed to deliver proven Trane performa nce based on the redesign of a European model that has been a market leader, plus all the benefits of new heat transfer and fan desi gns, as well as, low-speed, direct-drive scroll compressors. Important Design Features and New FeaturesPackaged systems. Simplify your comfort with all-in-one HVAC systems that bundle heating and cooling components in a single box. Unlike split systems, these systems only use one outdoor unit and work best in mobile and modular homes or homes without basements or attics. Gas & electric packaged. Create optimal comfort with an air conditioner and ...Chillers. Trane has one of the industry's largest portfolios of chiller-heaters, ranging from 20 to 4,000 tons. Compare heat recovery vs heat pump equipment and learn about their basic functionality here.Trane is a manufacturer of commercial and residential heating, ventilation, and air conditioning (HVAC) systems, along with building management systems and controls. …This tradition of using ex cellence to meet market demands is illustrated with the Trane 20 to 130 ton air-cooled scroll chiller. This next-generation chiller is an exciting step forward in energy-efficiency, sound, reliability, ease of serviceability, control precision, application versatility, and ... † Updated digit -37 in the model number description. † Updated …Capacity Range: 20 to 130 tons (50 and 60 Hz) Refrigerant: R-410A Energy Efficiency Rating (EER): IPLV: 13.7-16.6 (high-efficiency); 14.5-16.9 (extra-high-efficiency) Sintesis® Air-Cooled Chillers At a Glance: Capacity Range: 115 to 520 tons Refrigerant: R-134a or R-513A Compressor Design: Helical rotary screwI forget what the trane is, but probably the same McQuay chillers m# PEH079 S# 5YC0100700 style 0547362010 m# PEH076 S# 5ZA81012-01 style 9566323018 trane screw centravac m# RTHA130FCMONDUC3LF2LFNN00GUQ S# U90K03031 device# 3036RT130 appreciate it building engineer would like something more than a shoot from the hip nominal tonnage.Liquid Chillers 70-250 Tons Model RTWD Water-Cooled 70-200 Tons Model RTUD Condenserless Made in USA ... Trane is proud to introduce the model RTWD helical-rotary liquid chiller. To meet a wide range of applications in the 70-200 ton condenserless market, Trane is offering the RTUD condenserless chiller. The ... Model Number Descriptions ...Model Number: RTHD · Year: 2011 · 300 Tons Nominal Cooling · 460V/3Ph/60Hz · Refrigerant: R-134a · Rotary Screw Compressor · Shell & Tube Condenser Heat Exchanger ... Trane chiller tonnage by model number, Trane Commercial Parts. Founded in 1885 as a family plumbing business, Trane, Inc. is a leading manufacturer of HVAC systems. It manufacturers commercial units like: Water-Cooled, Air-Cooled & Modular Chillers. P Series, NV Series & N-Gen Ductless Systems. Rooftop, Split & Self-Contained Packaged Units. , Probably a 200 ton, since that is what the building prints say. The tonnage in Trane's model number is for the machine's nominal tonnage. The actual, or design, tonnage may or may not be the same. In your case it is not the same. Each chiller is designed to the tonnage specced for that job. In many cases it results in some modifications to a ..., Digits 1, 2 — Unit Model RT = Rotary Chiller Digit 3 — Unit Type A= Air-cooled Digit 4 — Development Sequence F = Development Sequence Digits 5-7 — Nominal Capacity 500 = 500 Nominal Tons Digit 8— Unit Voltage C = 380/60/3 G = 400/60/3 Digit 9 — Manufacturing Location U = Trane Commercial Systems, Pueblo, CO USA, Điều hòa chiller trane. Helical Rotary Liquid Chiller 125-450 Ton 423.000.000 đ Tiết kiệm điện: Chiller Trane. Model: RTUD 80 to 250 Tons. 289.000.000 đ Tiết kiệm điện: Chiller trục vít Trane. Model: CGAM 20 to 130 tons (50 and 60 Hz) 98.000.000 đ Tiết kiệm điện: Điều hòa Chiller Trane giải nhiệt nước., ©2020 Trane CG-PRC017Q-EN Introduction Design and manufacturing excellence makes Trane a leader in the air-cooled chiller market place. This tradition of using ex cellence to meet market demands is illustrated with the Trane 20 to 130 ton air-cooled scroll chiller. This next-generation chiller is an exciting step forward in energy- , Models:CVHE, CVHF, CVHG X39641075150 SAFETY WARNING Only qualified personnel should install and service the eq uipment. The installation, starting up, and servicing of …, ©2020 Trane 22-1901-1J-EN SAFETY SECTION Important — This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. ... (All 115K Models) BAYLPKT100A [ ] LP Conversion Kit (All 60K and 90K Models) BAYLPKT101A [ ], We create comfortable, energy efficient indoor environments for commercial and residential applications., As the original manufacturer, Trane branded R-22 and R-410A, 6.2 ton - 30 ton, light commercial & commercial scroll compressors are built to the same tolerances ..., 10 CLCH-PRC022F-EN FeaturesandBenefits Figure1. Traneperformanceclimatechangerairhandler Form,FunctionandFlexibility ..., Trane XL16i: · 4TTX6024A 4TTX6036A 4TTX6048A 4TTX6060A · 2 Tons ; Trane XR15: · 4TTR5018E 4TTR5024E 4TTR5030E 4TTR5036E 4TTR5042E 4TTR5048E 4TTR5049E 4TTR5060E, ©2020 Trane 22-1901-1J-EN SAFETY SECTION Important — This document contains a wiring diagram, a parts list, and service information. This is customer property and is to remain with this unit. ... (All 115K Models) BAYLPKT100A [ ] LP Conversion Kit (All 60K and 90K Models) BAYLPKT101A [ ], RLC-PRC049J-EN 9 ApplicationConsiderations Certainapplicationconstraintsshouldbeconsideredwhensizing,selecting,andinstallingTrane chillers ... , The CGAM air-cooled scroll chiller offers the perfect combination of flexibility, efficiency and low noise. Available in sizes ranging from 20 to 130 tons with a compact footprint, the CGAM is one of the quieter air-cooled chillers available today. Multiple levels of efficiency to choose from allow you to comply with your local code requirements. , Our chillers serve HVAC systems that deliver the right temperature, humidity and ventilation for the space, but they also help minimize operating costs with superior energy efficiency levels, low sound levels and with minimal environmental impact. water-cooled-rthd-chiller.jpg. , Helical-Rotary Liquid Chiller Model RTHC, 550–1600 kW Reliable Sources of Chilled Water. T rane is a leading manufacturer of helical-rotary ... comprised of Trane HVAC equipment, integral unit controllers, and building management, designed and commissioned with Trane application expertise. It provides comfort, efficiency, ... Literature Order Number RLC …, CenTraVac Water-Cooled Chiller. At a glance. Capacity Range: 120 to 4,000+ tons, 60/50 Hz. Refrigerant: R-514A and R-1233zd Compressor. Best Full-load Efficiency: 0.4872 kW/ton (at AHRI conditions) Best Part-load Efficiency: 0.3055 kW/ton. Compressor type: Centrifugal. , Trane’s air-to-water heat-pump chiller provides cooling or heating from one all-electric source, making it an effective—and more affordable—way to decarbonize. 3X more efficient. Ascend model ACX brings Trane’s proven, economical heat pump technology platform up to scale to provide heating or cooling for larger commercial, ©2023 Trane CG-PRC017T-EN Introduction Design and manufacturing excellence makes Trane a leader in the air-cooled chiller market place. This tradition of using excellence to meet market demands is illustrated with the Trane 20 to 130 ton air-cooled scroll chiller. This next-generation chiller is an exciting step forward in energy-efficiency ..., ©2022 Trane RLC-PRC049K-EN Introduction The new Trane® Sintesis™ model RTAF chiller is the result of a search for higher reliability, higher energy efficiency, and lower sound levels for today’s environment. Sintesis™ is the newest member of Ingersoll Rand’s EcoWise™ portfolio of, Model Number Descriptions Unit Model Number Digits 1, 2 - Unit Model RT = Rotary chiller Digit 3 - Unit Type A= Air-cooled Digit 4 - Development Sequence C = Development sequence Digits 5, 6 and 7 - Nominal Capacity 120 = 120 Nominal tons 130 = 130 Nominal tons 140 = 140 Nominal tons 155 = 155 Nominal tons 170 = 170 Nominal tons, Voyager 3 - 27.5 - 50 Tons. Nominal Cooling Ton Size. AHRI Efficiency IEER (STD Cooling Only/ VAV Fan) AHRI Efficiency IEER (HI Cooling/ VAV Fan) Low Modulating Gas Heating (Input/Output) (MBtuh) High Gas Heating (Input/Output) (MBtuh) High Modulating Gas Heat Turndown. Approx. Unit Weight (lbs) Cooling Only. 27.5., MODEL. 4TTZ0024A1 4TTZ0036A1 4TTZ0048A1 4TTZ0060A1. TONS. ... Trane 2/4TEE Air Handler: ... 4 Ton 5 Ton. Cooling Capacity (BTHU) 18,000 BTHU, We have 1 Trane YCH600 manual available for free PDF download: ... Model Number Description. 14. General Data. 15. Performance Adjustment Factors. 18. Performance Data. 19. ... Air Conditioner Heat Pump Chiller Air Handlers Thermostat. More Trane Manuals . manualslib. Our app is now ..., Models:CVHE, CVHF, CVHG X39641075150 SAFETY WARNING Only qualified personnel should install and service the eq uipment. The installation, starting up, and servicing of …, Trane®Air-Fi®WirelessCommunicationInterface X Trane®CommunicationInterface X Note:Formoreinformation,referencetheControlschapter. (a) ... (YHC)models. Typical5tonTHC060E OAConditions RAconditions 2000cfmTotalSupplyAirflow Partloaddayandraining 75ºFdb 800cfmOutsideAir(40%) ..., Brand History: Early 1900's - Started as McQuay Radiator in Minneapolis, MN and manufactured radiators for the Ford Model-T. 1933- Incorporated as McQuay Inc. and initial HVAC success was built on the first classroom unit ventilator and the first hermetic compressor for air conditioning use.; 1941-1945 - McQuay manufacturing facilities were …, Packaged Rooftop Air Conditioners Precedent™ — Gas/Electric 3 to 10 Tons — 60 Hz Installation, Operation, and Maintenance January 2021 RT-SVX21AC-EN Model Numbers: YSC036G - YSC060G YHC072F - YHC102F Model Numbers: YSC072H - YSC120H YHC120F Model Numbers: YHC036E - YHC072E YHC037E - YHC067E, Model: HDWA PC 747 ©2022 Trane HDWA-PRC004B-EN Introduction Compact Chillers That Fit Your Needs ... The quality management system used by the Trane Agility™ chiller manufacturing facility is the ISO 9001 Standard. This standard documents office, manufacturing, and testing procedures for maximum consistency in meeting or …, Whether you need a York furnace model number or a Goodman furnace model number, it’s a good idea to know where to find furnace model numbers and how to decode them. These numbers are essential when searching for replacement parts., Điều hòa chiller trane. Helical Rotary Liquid Chiller 125-450 Ton 423.000.000 đ Tiết kiệm điện: Chiller Trane. Model: RTUD 80 to 250 Tons. 289.000.000 đ Tiết kiệm điện: Chiller trục vít Trane. Model: CGAM 20 to 130 tons (50 and 60 Hz) 98.000.000 đ Tiết kiệm điện: Điều hòa Chiller Trane giải nhiệt nước., T = Trane Model Number CMB = Branch Controller UNIT TYPE M = Main S = Sub G = Single # OF BRANCHES 0104 = 4 Branches 0106 = 6 Branches 0108 = 8 Branches 1012 = 12 Branches 1016 = 16 Branches UNIT APPLICATION SJ1 = J1 Single JA1 = JA1 Main KA1 = KA1 Main KB1 = KB1 Sub VOLTAGE 1 = 208/230V/1P/60Hz GENERATION CODE N = …, AC Tonnage = 2.5 Tons. You can get AC tonnage by the general estimation that the digits “30” indicate 30,000 BTU of cooling capacity in your air conditioner. As 12,000 BTU is the …